Model test on detection of intercalated mud bored pile using optical fiber sensing technology

LEI Wen-kai1, 2, XIAO Heng-lin2, ZHANG Jin-tuan1, LIU Yong-li2, FAN Meng2, 3   

  1. 1. School of Construction Engineering, Hezhou University, Hezhou, Guangxi 542899, China; 2. Institute of Geotechnical Engineering and Underground Construction, Hubei University of Technology, Wuhan, Hubei 430068, China; 3. Xiamen Municipal Engineering Design Institute Ltd., Xiamen, Fujian 361000, China
  • Received:2016-03-21 Online:2018-03-12 Published:2018-06-06
  • Supported by:

    This work was supported by the National Natural Science Foundation of China (51578219), Hubei Provincial Key Project of Science and Technology Department (2012FFB00606) and the High Level Talent Project of Hubei University of Technology (BSQD12054).

摘要: 将分布式光纤传感技术用于夹泥灌注桩定量检测。建立了加热光纤与桩身介质的单层圆筒壁一维传热模型,利用桩体中光纤的温升变化规律检测夹泥桩的含泥量。开展含泥量分别为0、33.3%、50.0%、66.7%、100.0%的夹泥桩光纤检测模型试验,确定合适的加热功率范围和加热时间,并对光纤传感器进行标定,研究不同夹泥桩中光纤温升变化情况和桩身介质导热系数,发现在相同加热功率下,随着含泥量增大,光纤温升速率变快、增加幅度变大。进一步分析表明,含泥量与桩身介质导热系数之间存在确定的线性关系,并推导出两者数量关系式。通过声波检测对比试验,分析了该技术的测量精度。结果表明,桩体含泥量大于10%时,光纤检测法的精度与声波检测法较为接近。通过以上研究,为定量检测灌注桩的完整性提供了一种思路。

关键词: 光纤传感, 夹泥灌注桩, 检测, 含泥量

Abstract: Distributed optical fiber sensing technology was applied to the quantitative detection of intercalated mud bored pile. One dimensional model was proposed to simulate the heat transfer of single-layer cylindrical wall made up of heating fiber and pile body medium . Mud content of pile was detected by the variety of temperature rise of optical fiber in the pile. Intercalated mud pile model tests of optic fiber detection were designed with the mud contents of 0, 33.3%, 50%, 66.7% and 100%. After the calibrating of fiber optic sensor, the temperature rise and thermal conductivity coefficient of piles were investigated under appropriate range of heating power and heating time. It was founded that the rate of temperature rise of the fiber was increased with the mud content under the same heating power. Further analysis showed that there is a good linear relationship between mud content and thermal conductivity coefficient of pile. At last, the accuracy of this technique was analyzed by acoustic wave test. The results showed that the accuracy of optic fiber detection method is close to that of the acoustic wave detection method when the mud content of pile is more than 10%. This studies provided a way for quantitative detection of pile integrity.

Key words: optical fiber sensing, intercalated mud bored pile, detection, mud content

中图分类号: 

  • TU 473

[1] 侯公羽, 胡涛, 李子祥, 谢冰冰, 肖海林, 周天赐, . 基于分布式光纤技术的采动影响下覆岩 变形演化规律试验研究[J]. 岩土力学, 2020, 41(3): 970-979.
[2] 李立, 余翠, 孙涛, 韩增强, 唐新建, . 基于颜色特征的数字钻孔图像溶隙结构识别方法[J]. 岩土力学, 2019, 40(8): 3274-3281.
[3] 赵兰浩, 芮开天, 刘勋楠. 非均匀颗粒快速线性接触检测算法[J]. 岩土力学, 2019, 40(3): 1187-1196.
[4] 葛云峰, 钟鹏, 唐辉明, 赵斌滨, 王亮清, 夏丁, 仇雅诗, 李鹏飞, 张莉, 闻炼, 曹天赐, . 基于钻孔图像的岩体结构面几何信息智能测量[J]. 岩土力学, 2019, 40(11): 4467-4476.
[5] 李国维, 施赛杰, 侯宇宙, 吴建涛, 李 峰, 吴少甫, . 引江济淮试验工程非膨胀土开发技术实验研究[J]. 岩土力学, 2018, 39(S2): 302-314.
[6] 程 壮,王剑锋. 用于颗粒土微观力学行为试验的微型三轴试验仪[J]. , 2018, 39(3): 1123-1129.
[7] 苗鹏勇,王宝军,施 斌,张其琪. 特征点压缩算法在分布式光纤桩基检测中的应用[J]. , 2017, 38(3): 911-917.
[8] 刘新荣,王子娟,傅 晏,袁 文,邓志云, . 不同含水率砂岩无损检测参数的尺度效应研究[J]. , 2016, 37(S1): 192-200.
[9] 金 林,胡新丽,谭福林,何春灿,章 涵,张玉明. 基于红外热成像技术的抗滑桩土拱效应模型试验研究[J]. , 2016, 37(8): 2332-2340.
[10] 孙熙震,李杨杨,江 宁,沈宝堂. 类岩石材料三维裂纹传播规律试验研究[J]. , 2016, 37(4): 965-972.
[11] 孟上九 ,张书荣 ,程有坤 ,汪云龙 ,王 钰 ,孙义强,. 光纤布拉格光栅在季节冻土路基应变检测中的应用[J]. , 2016, 37(2): 601-608.
[12] 汪 魁,赵明阶,孙 笑. 填方地基压实质量的波电场耦合快速检测试验研究[J]. , 2015, 36(S2): 413-418.
[13] 孙熙平,张 勇,郑锋勇,齐广政. 高桩码头基桩竖向承载力原型试验研究[J]. , 2014, 35(9): 2609-2615.
[14] 刘 钢 ,罗 强 ,张 良 ,陈 虎 ,陈 坚,. 铁路路基压实质量检测中的小型平板载荷试验分析[J]. , 2014, 35(6): 1687-1694.
[15] 寇海磊 ,张明义,. 基于桩身应力测试的静压PHC管桩贯入机制[J]. , 2014, 35(5): 1295-1302.
Viewed
Full text


Abstract

Cited

  Shared   
  Discussed   
No Suggested Reading articles found!