Rock and Soil Mechanics ›› 2020, Vol. 41 ›› Issue (12): 3947-3956.doi: 10.16285/j.rsm.2020.0418

• Fundamental Theroy and Experimental Research • Previous Articles     Next Articles

Experimental study of hydraulic conductivity reduction induced by Al-OM flocs-clogging

ZHAO Hong-fen1, 2, ZHOU Zhi-xin1   

  1. 1. School of Civil Engineering, Sun Yat-sen University, Guangzhou, Guangdong 510275, China; 2. Southern Marine Science and Engineering Guangdong Laboratory (Zhuhai), Institution of South China Sea Ecology and Environmental Engineering, Chinese Academy of Sciences, Zhuhai, Guangdong 510301, China
  • Received:2020-04-10 Revised:2020-06-09 Online:2020-12-11 Published:2021-01-18
  • Supported by:
    This work was supported by Young Scholars of the National Natural Science Foundation of China(51909287) and the Natural Science Foundation of Guangdong Province(2020A1515010872).

Abstract: Anti-seepage is of great significance on hydraulic engineering such as dikes, underground engineering and pollutant migration. Based on the formation of impermeable soil layers due to the complexation between metal ions and organic matter during the formation of natural podzolic soil layer, a novel approach was proposed to reduce soil permeability by Al-OM flocs formed by the interaction between aluminum chloride (AlCl3·6H2O) and organic matter (OM). Extensive laboratory tests were conducted to investigate the effects of slurry concentration, injection rate and the particle size distribution of sand on the reduction of hydraulic conductivity and the distance of flow barrier. The results showed that the Al-OM flocs could significantly reduce the soil permeability. As the concentration of Al-OM flocs in the slurry increased, the decreasing rate of hydraulic conductivity also increased. This is because due to the increase in the concentration of Al-OM flocs, the rate of pore clogging increased, which prevented it from diffusing further, thus reduced the length of flow barrier. The size of Al-OM flocs decreased with the increasing injection rate. When the injection rate was larger, the size of Al-OM flocs was small, so the reduction of hydraulic conductivity was slower and the diffusion distance of Al-OM flocs was longer. The particle size distribution of sand had a significant impact on the reduction of hydraulic conductivity. The higher the coarse particle content was, the slower the reduction of hydraulic conductivity was.

Key words: Al-OM flocs, anti-seepage, slurry concentration, injection speed, particle-size distribution

CLC Number: 

  • TU411.4
[1] JIAO Wei-guo , TU Bin, ZHANG Song, HE Ming-wei, LIN Chang-song, LIU Zhen-nan, . Anti-seepage performance verification and analysis of high-risk permeable meteorological period of capillary barrier cover in Northwest non humid area [J]. Rock and Soil Mechanics, 2023, 44(S1): 539-547.
[2] YU Jun, LI Dong-kai, HE Zhen, ZHANG Zhi-zhong. Analytical solution of anisotropic seepage in dam foundation with anti-seepage walls at both ends [J]. Rock and Soil Mechanics, 2023, 44(8): 2381-2388.
[3] LI Ning, PAN Hang, ZHANG Mao-jian, ZHANG Hui-li, LI Xin-zhen, XU Jian-cong, . Influence of rainfall patterns on anti-seepage performance of capillary barrier covers [J]. Rock and Soil Mechanics, 2022, 43(6): 1546-1556.
[4] ZHU Cai-hui, LI Ning, MA Shuai, CUI Chen, DONG Xue-qin, . Study on anti-seepage measures of rammed earth foundation of ancient buildings based on model test [J]. Rock and Soil Mechanics, 2021, 42(12): 3281-3290.
[5] LIU Zheng-hong, ZHANG Long, ZHENG Jian-guo, ZHANG Wei, YU Yong-tang, . Testing device and experimental study on anti-seepage ability of sliding micrometer tube [J]. Rock and Soil Mechanics, 2020, 41(7): 2504-2515.
[6] NIU Ya-qiang , WANG Xu , ZHENG Jing , JIANG Dai-jun , LIU De-ren , JIANG Peng-cheng , . Experimental research on anti-seepage effect of new embankment structure of lateral-constraint and seepage control [J]. , 2015, 36(S2): 252-258.
[7] WAN Yong ,XUE Qiang ,ZHAO Li-ye ,DU Yan-jun ,LIU Lei,. Effects of wetting-drying cycles on permeability of compacted clay cover at landfill site [J]. , 2015, 36(3): 679-686.
[8] PENG Peng ,SHAN Zhi-gang ,WANG Yong-ming ,JIA Hai-bo ,DONG Yu-fan . Anti-seepage effect of curtain under dam foundation and its durability based on saturation index model [J]. , 2013, 34(1): 221-226.
[9] XU Shang-jie ,DANG Fa-ning ,CHENG Su-zhen. Research of muddy water seepage theory and anti-seepage technique for plain reservoirs [J]. , 2011, 32(7): 2093-2098.
[10] LIU Ji-shan. A hydraulic anti-seepage curtain scheme and post-evaluation technique [J]. , 2010, 31(S2): 360-365.
[11] PENG Peng,SONG Han-zhou,XU Jian-guang,GUO Zhang-jun. Anti-seepage evaluation of dam foundation curtain based on Bayes data fusion theory [J]. , 2010, 31(9): 2889-2893.
[12] XIE Xing-hua, WANG Guo-qing. A study of anti-seepage wall depth in thick overburden dam base [J]. , 2009, 30(9): 2708-2712.
[13] CHEN Jun-feng, FENG Mei-guo. Study of anti-seepage measures for foundation pit based on saturated-unsaturated seepage theory [J]. , 2009, 30(5): 1425-1430.
[14] PENG Peng, SONG Han-zhou, GUO Zhang-jun. Study of macroscopic regime of groundwater under dam section based on data fusion theory [J]. , 2009, 30(12): 3820-3824.
[15] LU Ying-fa, CHENG Zhu-lei, XIE Wen-liang, Lü Zhi-zhong. Application of geotechnics to sanitation landfill of refuse [J]. , 2009, 30(1): 91-98.
Viewed
Full text


Abstract

Cited

  Shared   
  Discussed   
No Suggested Reading articles found!