Rock and Soil Mechanics ›› 2021, Vol. 42 ›› Issue (11): 2919-2924.doi: 10.16285/j.rsm.2021.0725

• Fundamental Theroy and Experimental Research •     Next Articles

A calculation method for the bearing capacity of saturated soil under undrained conditions

SONG Er-xiang1, 2, FU Hao1, 2, LI Xian-jie1, 2   

  1. 1. Department of Civil Engineering, Tsinghua University, Beijing 100084, China; 2. Key Laboratory of Civil Engineering Safety and Durability of the Ministry of Education, Tsinghua University, Beijing 100084, China
  • Received:2021-05-13 Revised:2021-07-20 Online:2021-11-11 Published:2021-11-11
  • Supported by:
    This work was supported by the National Natural Science Foundation of China (51778339) and the National Basic Research Program of China (2014CB047003).

Abstract: With regard to undrained analysis of saturated clay foundation for its ultimate bearing capacity under rapid loading, this study has proposed the calculation of the unconsolidated-undrained (UU) strength instead of employing the consolidated-undrained (CU) strength parameters directly due to overestimated results. The formula for predicting UU strength has been deducted based on the CU strength parameters referring to the reports of geological investigation, and the profile of the UU strength , found increases linearly with depth, has been built up. A calculation method for the bearing capacity of this foundation type is therefore proposed. The basic idea thereof is to use the value of at the average depth of the slip plane in the calculation, and a dimensionless parameter, which plays the key role, is introduced to determine the maximum depth of the slip surface. The accuracy and the precision of this parameter, as well as the proposed method, has been validated via a large number of comparative calculations with the finite element limit analysis method in this study.

Key words: bearing capacity of foundation, saturated clayey soil, unconsolidated-undrained strength, consolidated-undrained strength parameter

CLC Number: 

  • TU 470
[1] YUAN Yu, LIU Run, FU Deng-feng, SUN Guo-dong. Secondary development and application of structural marine clay damage model [J]. Rock and Soil Mechanics, 2022, 43(7): 1989-2002.
[2] SONG Er-xiang, CHEN Xing-yi, LIN Shi-jie. On the checking methods for bearing capacity of foundation under eccentric loading [J]. Rock and Soil Mechanics, 2022, 43(7): 1925-1932.
[3] YANG Guang-hua, HUANG Zhi-xing, JIANG Yan, ZHANG Yu-cheng, . Double controlling method for determining bearing capacity of foundation soils [J]. , 2016, 37(S2): 232-242.
[4] YANG Yang,LU Kun-lin,ZHU Da-yong. Study of bearing capacity of weightless foundation under local shear failure mode [J]. , 2014, 35(1): 232-237.
[5] YANG Lei, HE Wei-min, ZHOU Yang, ZHANG Qing-ming. Optimal design of deep-mixing pile composite foundation [J]. , 2010, 31(8): 2575-2579.
[6] WANG Zhe , WANG Guo-cai , CHEN Yu , CHEN Jian-guo  . Theoretical solution of ultimate bearing capacity of foundations under shallow rectangular footings [J]. , 2008, 29(4): 1001-1004.
[7] DENG Chu-jian, KONG Wei-xue, ZHENG Ying-ren. Analysis of ultimate bearing capacity of foundations by elastoplastic FEM through step loading [J]. , 2005, 26(3): 500-504.
[8] ZHENG Ying-ren,ZHAO Shang-yi, KONG Wei-xue, DENG Chu-jian . Geotechnical engineering limit analysis using finite element method [J]. , 2005, 26(1): 163-168.
Viewed
Full text


Abstract

Cited

  Shared   
  Discussed   
No Suggested Reading articles found!