›› 2017, Vol. 38 ›› Issue (2): 317-324.doi: 10.16285/j.rsm.2017.02.002

• Fundamental Theroy and Experimental Research • Previous Articles     Next Articles

Pull-out test study of interface behavior between triaxial geogrid and soil

ZHENG Jun-jie, CAO Wen-zhao, ZHOU Yan-jun, JIANG Jin-guo   

  1. Institute of Geotechnical and Underground Engineering, Huazhong University of Science and Technology, Wuhan, Hubei 430074, China
  • Received:2015-03-23 Online:2017-02-11 Published:2018-06-05
  • Supported by:

    This work was supported by the National Natural Science Foundation of China (51278216), the National Natural Science Foundation of Hubei Province (2013CFB180) and the Graduates’ Innovation Fund of Huazhong University of Science & Technology (HF-11-13-2013).

Abstract: Most of the existed studies of soil-geogrid interaction mainly focus on uniaxial and biaxial geogrids. Nevertheless, the interface behavior between triaxial geogrid and soil has not been fully understood by experimental study. A series of laboratory pull-out tests is conducted on triaxial geogrid considering the effect of two kinds of pullout directions, referred to as TX_0 and TX_90, respectively. The displacements of specimens are measured and recorded at 4 sections along the pullout direction, and then the tensile strain, relative displacement between geogrid and soil, distribution pattern of interface friction, and deformation and failure mode of the geogrid specimens are all analyzed. Based on the peak shear strength and the residual shear strength, the variation laws of the interface behavior between geogrid-soil and apparent friction coefficient are investigated. The experimental results demonstrate that the interlocking of transverse rib increases with the increase of normal stress due to out-of-plane bending in the case TX_0, which leads to a better pullout performance than that in the case TX_90. The interface friction develops in a progressive mode along with constant adjustment of the distribution pattern and an elastoplastic softening characteristic is observed for interface behavior. The interface friction angles in the case TX_0 are significantly larger than that in the case TX_90, while the interface cohesions are just opposite. Higher normal stress can contribute to a better pullout performance in the case TX_0.

Key words: triaxial geogrid, pull-out test, pullout direction, interface behavior between geogrid and soil, geogrid deformation

CLC Number: 

  • U 461.1

[1] FENG Jun, WANG Yang, ZHANG Yu-feng, HUANG Lin, HE Chang-jiang, WU Hong-gang, . Experimental comparison of anchorage performance between basalt fiber and steel bars [J]. Rock and Soil Mechanics, 2019, 40(11): 4185-4193.
[2] ZHAO Xiang-zhuo, ZHANG Hong-wei, CAO Chen , ZHANG Ming,. Optimisation of bolt rib spacing and anchoring force under different conditions of surrounding rock [J]. , 2018, 39(4): 1263-1270.
[3] CUI Qiang, CHENG Yong-feng, LU Xian-long, XIE Feng, SUN Fu-tao, . In-situ pull-out test and parametric study of load-displacement model for hole digging foundation in the strong weathered rock mass [J]. Rock and Soil Mechanics, 2018, 39(12): 4597-4604.
[4] WANG Zong-jian, MA Shu-wen, LU Liang,. Study of reinforced soil adjusted to differential settlement based on parabolic cable theory [J]. , 2017, 38(11): 3319-3324.
[5] CAI Jian-tao. Pull-out test on interface behavior between expansive soils and geogrids [J]. , 2015, 36(S1): 204-208.
[6] MIAO Chen-xi ,ZHENG Jun-jie ,CUI Ming-juan ,XIE Ming-xing ,ZHAO Jian-bin,. Discrete element simulation of interface characteristic and frictional properties of triaxial geogrid [J]. , 2014, 35(S1): 423-430.
[7] MIAO Chen-xi ,ZHENG Jun-jie ,CUI Ming-juan ,XIE Ming-xing ,ZHAO Jian-bin,. Study of influence of joint protuberance on geogrid reinforcement performance by discrete element method [J]. , 2014, 35(4): 1181-1186.
[8] CAI Chun ,ZHANG Meng-xi ,ZHAO Gang-fei ,LI Jie1,WU Li-wei. Pull-out test of uniaxial geogrid with strengthening ribs [J]. , 2012, 33(1): 53-59.
[9] CHEN Jian-feng, LI Hui-li, LIU Jun-xiu, ZHOU Jian. Mesoscopic study of interface properties of geogrid-reinforced soil [J]. , 2011, 32(S1): 66-71.
[10] XU Chao, LIAO Xing-yue. Researches on interacton mechanism between geogrid and sand by pull-out tests [J]. , 2011, 32(2): 423-428.
[11] LI Qi-ren, WANG Ming-yuan, CAI Jian-tao, SHI Ge-liang. Effect of water content on pull-out behavior of interface between geogrid and compacted expansive soil [J]. , 2010, 31(S2): 175-178.
[12] TANG Chao-sheng,SHI Bin,GAO Wei,LIU Jin. Single fiber pull-out test and the determination of critical fiber reinforcement length for fiber reinforced soil [J]. , 2009, 30(8): 2225-2230.
[13] SHI Dan-da,LIU Wen-bai,SHUI Wei-hou,LIANG Yong-hui. Comparative experimental studies of interface characteristics between uniaxial/biaxial plastic geogrids and different soils [J]. , 2009, 30(8): 2237-2244.
[14] CHEN Rong,LUAN Mao-tian,ZHAO Wei,XU Xiao-yan,HAO Dong-xue. Research on pull-out test and frictional resistance characteristic of geogrids [J]. , 2009, 30(4): 960-964.
[15] HE Ruo-lan ,ZHANG Ping ,LIU Bao-chen,. Theoretical and numerical analysis of bolt pull-out test [J]. , 2006, 27(S1): 855-859.
Viewed
Full text


Abstract

Cited

  Shared   
  Discussed   
No Suggested Reading articles found!